Back

SCM – SINGLE CONTROL MODULE

This product is part of ENCASED THERMOSTATS
Relevant applications:

Description

Multi-function plastic housing with a 1-pole capillary control.

 

Features

  • Suitable for surface mounted, immersion and air applications
  • Multiple mounting configurations
  • Includes GTL series control with changeover contact
  • Control knob with temperature indication
  • Knob rotation customizable with stops
  • Customized colors and marking available

 

Operation

A rise in temperature causes the expansion of liquid within the bulb and capillary.  The liquid acts on a bellows assembly within the plastic housing to open and close electrical contacts.

Technical characteristics
  • THP
  • THA
  • TAM
Type For immersion with control bulb in brass pocket fitted directly on the housing. Limiter model : THPHR
Temperature range 0 to 90°C / 32 to 194°F
Adjustment Control knob
Rating 20A - 250V
Material Copper, stainless steel
Capillary length Up to 3000mm / Up to 118"
Protection Up to IP54
Connections Screw terminals
Accessories Jacket, necklace and bracelet mounting
Approvals CE conformity, ENEC MARKK according to EN 60730-1, EN60730-2-9, ROHS conformity
Type For surface mount with control bulb built into the back of the housing. Limiter model : THAHR
Temperature range 0 to 90°C / 32 to 194°F
Adjustment Control knob
Rating 20A - 250V
Material Copper, stainless steel
Capillary length Up to 3000mm / Up to 118"
Protection Up to IP54
Connections Screw terminals
Accessories Jacket, necklace and bracelet mounting
Approvals CE conformity, ENEC MARKK according to EN 60730-1, EN60730-2-9, ROHS conformity
Type For industrial ambient with capillary and bulb for deported temperature sensing
Temperature range 0 to 90°C / 32 to 194°F
Adjustment Control knob
Rating 20A - 250V
Material Copper, stainless steel
Capillary length Up to 3000mm / Up to 118"
Protection Up to IP54
Connections Screw terminals
Accessories Jacket, necklace and bracelet mounting
Approvals CE conformity, ENEC MARKK according to EN 60730-1, EN60730-2-9, ROHS conformity